Radon System Gauges and Alarms: How to Read Them

That small U-shaped tube on your radon pipe is the quickest way to know the system is working.

Call (629) 201-4576

Quick answer: Most active radon systems have a U-tube manometer, a small clear tube of colored liquid mounted on the vent pipe. When the fan is pulling suction, the liquid is higher on one side than the other. If both sides are level, the system is not drawing suction, usually because the fan is off, tripped or failed. Some systems also have an electronic pressure alarm that sounds or lights up when suction drops. Glance at the gauge every month or two and write down the normal reading. A big change either way is worth a call. A gauge only shows the fan is pulling; it does not measure radon, so the EPA still recommends retesting every two years.

Radon mitigation systems in Murfreesboro, Smyrna and the rest of Rutherford County are quiet by design. The fan sits in the attic, the garage or outside, and the pipe disappears into a closet or up an outside wall. That makes it easy to forget the system is there, and easy to miss when it stops. Warning devices exist so you don't have to guess.

Why systems have a warning device

An active radon system depends on a fan that runs all the time. The EPA's Consumer's Guide to Radon Reduction says that all active systems should have a warning device to alert you if the fan stops working properly. The radon mitigation standards published by AARST also call for a visible system indicator. Ask for one if your system doesn't have it.

The U-tube manometer

This is the most common indicator. It is a clear plastic tube bent into a U, partly filled with colored liquid, with one end connected to a small hole in the radon pipe and the other open to the room.

  • Fan running: the suction in the pipe pulls the liquid up on the pipe side, so the two columns are uneven.
  • Fan off or failed: no suction, so the two columns sit level.

The scale on the gauge shows the suction in inches of water column. The exact number depends on the fan, the soil under your slab and the pipe layout, so there is no single correct reading. What matters is your system's normal reading and whether it changes.

Talk it through with a certified pro. Free referral for Murfreesboro and Rutherford County homes.

(629) 201-4576

What changes in the reading can mean

  • Level (zero): the fan has no power or has failed. Check the breaker or GFCI outlet first.
  • Much lower than normal: possibly a weakening fan, a disconnected or cracked pipe, or a leak at a coupling.
  • Much higher than normal: possibly a blockage, such as ice at the discharge, water in the pipe, or debris, or a change under the slab. Higher suction with less airflow isn't better.
  • Bouncing liquid: some movement is normal on windy days. Constant wild swings are worth a look.

Electronic alarms

Some systems have a pressure switch or monitor that sounds an alarm or shows a light when suction drops below a set point. These are helpful when the gauge is in an attic or garage you rarely visit. Test or check the alarm as the manufacturer recommends, and replace batteries if it uses them. A plug-in digital radon monitor in the living space is a different thing: it measures radon in the air, not the fan's suction, and some homeowners use both.

A simple routine

  1. When the system is installed, write the normal reading on the label or take a photo.
  2. Check the gauge every month or two, and after storms or power outages.
  3. Listen for the fan. A steady hum is normal. See radon fan noise if the sound changes.
  4. Retest the home every two years, as the EPA recommends, and after major renovations.

Our radon system maintenance page has the full list, and radon system installation day explains how the gauge is set up in the first place.

A gauge is not a radon test

A manometer tells you the fan is pulling. It doesn't tell you the radon level in your living space. Soil conditions change, houses settle and new cracks appear. That is why the EPA recommends retesting after mitigation and every two years after that. See radon levels explained for what your results mean.

What affects a service quote

We don't publish prices. If your gauge has dropped to zero or changed a lot, a service quote depends on whether the fan needs replacing, whether pipe or couplings need repair, whether an alarm needs to be added, and how easy the fan is to reach. Call for a free quote.

Frequently asked questions

What should my radon manometer read?

There is no single right number. It depends on the fan, soil and pipe layout. Know your system's normal reading and watch for changes.

What does it mean if the radon gauge is level?

Both sides even means no suction. The fan is likely off, tripped or failed. Check the breaker or outlet first.

Does every radon system need an alarm?

The EPA says active systems should have a warning device, such as a U-tube manometer or an electronic alarm.

Does the manometer measure radon?

No. It shows the fan is pulling suction. Retest the home every two years to check the radon level.

Can weather change the reading?

Some bouncing on windy days is normal. Ice at the discharge in a cold snap can change the reading and should be checked.

Talk it through with a certified pro. Free referral for Murfreesboro and Rutherford County homes.

(629) 201-4576

Where this information comes from

Get a free radon quote

A certified local professional calls you back. Or call (629) 201-4576.

Your details go only to the professional who'll help you. Privacy policy.

Call for radon help (629) 201-4576